HAPRO ERROR CODES LUXURA

 
 
Голосов: 2
Оценить
Lumina C / E                          
                             
Code Description Possible problem / solution
                             
OVR Overrule: relais on main print defect Change main print
     
ERR Error airflow switch fan in bench Airflow switch not connected or defect
    Fan in bench does not work >> check wiring
            Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
     
PHS Phase failure Phase (L1,L2,L3 ) missing >> check wiring, check fuses
    Phase sensor on main print defect >> change main print
     
CON Communication failure Check data cable connection between display print and main print
            Change data cable or display print or main print
     
Blank display no display and fan in bench keeps working One of the blue filters (glass filter switch) is not closed correctly
            The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
            Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
            Data cable on display print not connected well
     
                             
                             
Luxura X3                          
                             
Code Description Possible problem / solution
                             
OVR Overrule: relais on main print defect Change main print
     
ERR Error airflow switch fan in bench Airflow switch not connected or defect
    Fan in bench does not work >> check wiring
            Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
     
PHS Phase failure Phase (L1,L2,L3 ) missing >> check wiring, check fuses
    Phase sensor on main print defect >> change main print
     
CON Communication failure Check data cable connection between display print and main print
            Change datacable or displayprint or mainprint
     
Blank display no display and fan in bench keeps working One of the blue filters (glass filter switch) is not closed correctly
            The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
            Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
            Datacable on display print not connected well
     
                             
             
Luxura X5, X7    
                             
Code Description Possible problem / solution
                             
E1 Overrule: relais on main print defect Change main print
     
E2 Error airflow switch fan in bench Airflow switch not connected or defect
    Fan in bench does not work >> check wiring
            Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
     
E6 Phase failure Phase (L1,L2,L3 ) missing >> check wiring, check fuses
    Phase sensor on main print defect >> change main print
     
E3 Communication failure Check data cable connection between display print and main print
            Change data cable or display print or main print
     
Blank display no display and fan in bench keeps working One of the blue filters (glass filter switch) is not closed correctly
            The temperature sensor (clixon) in the canopy is measuring high temp. >> check fan in canopy
            Too high temperature measured in canopy >> check exhaust pipe (too long / sharp angles)
            Data cable on display print not connected well
     
Airco service Airconditioning problem Condenswater in jerrycan has reached high level >> empty the jerrycan
            Levelswitch in jerrycan not working correctly >> check working
     
Stop button blinking General failure message Push the stop button and the display shows the error / message
     
                             
                             
Luxura X10                          
                             
Code Description Possible problem / solution
                             
Relais Failure + no. Overrule: relais on main print defect Change main print, number behind the message is the defective relais on the main print
     
Wind sensor failure Error airflow switch fan in bench Airflow switch not connected or defect
    Fan in bench does not work >> check wiring
            Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
     
Facial tanner service Problem in the facial burner area One of the blue filters (glass filter switch) is not closed correctly or defect
           
           
   
     
Communication failure Communication failure Check data cable connection between display print and main print
            Change data cable or display print or main print
     
Error overrule relay Overrule relais defect Overrule relais K14 defect >> change main print
     
Error Microcontroller Microcontroller defect One of the microcontrollers defect >> change main print
     
LF Controller LF Controller defect LF Controller (U9) on main print defect >> change main print
     
SC1 Controller SC1 Controller defect SC1 Controller (U10) on main print defect >> change main print
     
SC2 Controller SC2 Controller defect SC2 Controller (U7) on main print defect >> change main print
     
SC3 Controller SC3 Controller defect SC3 Controller (U5) on main print defect >> change main print
     
                             
                             
Luxura V5,V7                          
                             
Code Description Possible problem / solution
                             
E0 Unknown display Check the display print on correct version
     
E1 Relais failure defective relais on main print >> change main print
     
E2 Temperature failure The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof
    The temperature sensor (clixon) in one of the doors is defect
            Doors are not closed during the session
     
E3 Communication failure Check data cable connection between display print and main print
            Change data cable or display print or main print
     
E4 Main print failure Sense controller on main print defect >> change main print
     
                             
                             
Luxura V10                          
                             
Code Description Possible problem / solution
                             
E1 Overrule: relais on main print defect Change main print
     
E2 Communication failure Check data cable connection between display print and main print
    Change data cable or display print or main print
     
E3 Relais failure defective relais on main print >> change main print
     
Close doors   Doorswitch not closed (one is positioned in the service door, one on top of the right door)
            The temperature sensor (clixon) in the doors are measuring high temp. >> check fans roof
            The temperature sensor (clixon) in one of the doors is defect
            One of the blue filters (glass filter switch) in the doors is not closed correctly or defect
     
     
     
Seecret C500 /C700          
                             
Code Description Possible problem / solution
                             
E1 Overrule: relais on main print defect Change main print
     
E2 Error airflow switch fan in bench Airflow switch not connected or defect
    Fan in bench does not work >> check wiring
            Airflow switch does not come in normally > airflow blocked. Exhaust pipe too long / sharp angles
     
E5 Maximum Temperature NTC Heating PCB Check NTC element on Endcover feet side
    Check working bodycoolerfan
     
E3 Communication failure Check data cable connection between display print and main print
            Change data cable or display print or main print
     
E6 Phase failure One of the three phases is missing ?
           
           
           
     
E9 Maximum Temperature NTC Fan PCB Bench Check NTC element on Fan PCB frontpanel bench
            Check working mainfan
     
E10 Maximum Temperature NTC Fan PCB Canopy Check NTC element on Fan PCB in canopy
            Check working Canopy fan
     
E11 No communication with Fan PCB Bench Check datacables or defective Fan PCB
     
E12 No communication with Fan PCB Canopy Check datacables or defective Fan PCB

Есть вопросы?

Вы можете задать нам вопрос(ы) с помощью следующей формы.

Имя:

Email

Пожалуйста, сформулируйте Ваши вопросы относительно HAPRO ERROR CODES LUXURA:


Введите число, изображенное на рисунке
code