megasun 6800 7900 и другие горизонтальные солярии
E01BUS:ABL There is not any data link between the controller board and the
revolution control...
Reason: defective or not connected I²C revolution control.
E02:BUS:TMP Reason: defective or not connected I²C temperature sensor.
Solution: press the START key. The blower is running with max.
revolution during the temperature controll.
E04:BUS:VOIC Reason: There is not any data link between the controller board
and the MP3 player Voice.
Solution: press the START key. The controller is working as one
w/o megaVoice.
Reason:
— missing soldering bridge on MP3-Player megaVoice,
— SD card not readable
— formating or wrong inserted,
— Plug at MP3 iInterface or at I²C Audio switch is
inserted uncorrect.
E05BUS:REL Conguration error: I²C-Relay board (8) an I²C Relais board (2) at
the same time connected.
BUS-Error Daten line of the Bus I²C-Bus is disturbed
— 230 V is missing at MP3-Player or Audio Switch
— Bus connector at MP3-Player in wrong position
Error message
“Ende der
Besonnung“
„End of tanning
session“
This message will be displayed after 40 minutes of uninterrupted
operation of the tanning system.
By turning off the coin-operated system this message is
acknowledged.
Error message
“Abluft“ oder
“Windschalter“
This error messageis displayed on the operating panel and
can be acknowledged by pressing the “Stop“ key. Prior to this,
service staff has to nd the reasons of these error messages.
Possible reasons can be:
• temperature in the unit is too high
• exhaust vent system is defectiv
MegaSun Pure Energy вертикальные солярии
Faults nos. 07, 08, 12 and 13 do not occur with the KBL/5 processor due to its equipment and processor structure.
Temp. Err Exhaust
air, Excess
temperature
bimetal!
max. time Incoming enabling signal from
coin-box system longer than
approved, i.e. the value specified
under “Maximum tanning time”
(voltage remains connected).
> 66 °C The sensor has measured the
limit value of 66 °C.
> 62 °C A temperature exceeding 62 °C
is measured for more than 3
minutes.
1 sensor f One temperature sensor has not
been found by the control system.
2 sensor f Both temperature sensors have
not been found by the control
system. Ventilation works at
100 % power.
Aqua low The content of the aquaCool
canister is sufficient for another
750 spraying seconds (2.5
operating hours at a cycle
time = 1 minute).
Bus Error I²C bus faulty.
measur. f Temperature values outside the
range of 0 - 85 °C.
1-Wire f No connection to 1-wire-adaptor
(e.g. cable break). Bus cable or
1-wire bus adaptor defective.
Aqua 0% 750 spraying seconds (2.5
operating hours at a cycle time
= 1 minute) have expired.
Hardware
error Main board defective